VME-7807RC VME-7807RC-410000 350-930078074-410000 G
- 135 Piece / Pieces per Month
- T/T
- 1 days
Product Details
Brand Name: | GE | Place of Origin: | China | Model Number: | VME-7807RC VME-7807RC-410000 350-930078074-410000 G |
Product Description
Brand:GE
Type:VME-7807RC VME-7807RC-410000
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Spare parts spare parts, the main DCS control system of PLC system and the robot system spare parts,
Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Importing the Add-On Instruction 1 Open the application in Studio 5000. 2 Expand the TASKS folder, and expand the MAINTASK folder. 3 Expand the MAINPROGRAM folder. The MAINROUTINE contains rungs of logic. The very last rung in this routine is blank. This is where you can import the Add-On Instruction. Note: You can place the Add-On Instruction in a different routine than the MainRoutine. Make sure to add a rung with a jump instruction (JSR) in the MainRoutine to jump to the routine containing the Add-On Instruction. 4 Right-click an empty rung in the routine and choose IMPORT RUNGS.
Select the .L5X file that you exported from PCB (Creating and Exporting the .L5X File (page 24)). This opens the Import Configuration dialog box. Click TAGS under MAINROUTINE to display the controller tags in the Add-On Instruction. Note: If you are using RSLogix version 16 or earlier, the Import Configuration dialog box does not contain the Import Content tree.
If the module is not located in the default slot (or is in a remote rack), edit the connection input and output variables that define the path to the module in the FINAL NAME column (NAME column for RSLogix version 16 or less). For example, if your module is located in slot 3, change Local:1:I in the FINAL NAME column to Local:3:I. Do the same for Local:1:O. Note: If your module is located in Slot 1 of the local rack, this step is not required. 7 Click OK to confirm the import. 8 When the import is completed, the new rung with the Add-On Instruction is visible.
Adding Multiple Modules in the Rack (Optional) Important: This procedure is for multiple MVI69E-MBS modules running in the same CompactLogix or MicroLogix 1500-LRP rack. You can add additional modules of the same type to the rack. 1 Add a new MVI69E-MBS module to the ProSoft Configuration Builder (PCB) project. 2 Export the module configuration as an L5X file. 3 Add a new MVI69E-MBS to the Studio 5000 project. 4 Import the .L5X file into Studio 5000 for the new module as an Add-On Instruction. 2.5.1 Adding Another Module in PCB 1 Start ProSoft Configuration Builder. 2 Right click DEFAULT LOCATION (which you can rename) and choose ADD MODULE. 3 Right-click NEW MODULE and choose CHOOSE MODULE TYPE. 4 In the Choose Module Type dialog box, select MVI69E in the PRODUCT LINE FILTER area, and then select MVI69E-MBS as the MODULE TYPE. Click OK. 5 Select the MVI69E-MBS module in the tree and repeat the above steps to add a second (or more) module in the PCB project.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
- Vector Inverter VFD Frequency Converter 3 Phase Variable Frequency Drive Motor Speed Control AC DC inverter 50hz to 60hz 55KW
- General Used Vector Control Frequency Inverter(3phase 380V) 200kw
- For Building Data Acquisition HVAC Monitoring and Control BACnet/IP IO Module
- Supports VPN and TLS/SSL Data Encryption Flexible EdgeIO Controller
- 800PP846A Operation panel Provides greater visibility into the process
- TRICONEX 3721 Communication module Multiple sensors can be connected
- PM150V08 3BSE009598R1 High performance processor module Multiple control tasks can be handled simultaneously
- MS-NAE5510-3 Ethernet-based monitoring devices Higher data transfer rate
- triconex 3625C1 Digital output module The flexibility of the control system is improved
- triconex 3636R Automatic control module Supports multiple communication protocols
- KUC711AE101 3BHB004661R0101 Digital input module Ability to detect input signals in time
- CI541V1 3BSE014666R1 Interface module Connect and transfer data
- IS220PDIAH1B Turbine control PCB board
- UTV-F2500HA Manipulator controller Remote manipulator
- triconex 4329 Network communication module Ethernet (802.3) port
- Programmable Logic Controller MQTT IO Module for Distributed Data Acquisition and Control Systems
- IS215UCVEH2AB Standard mark VI controller Ethernet cable
- DS200SIOBH1ACA I/O control board There are 6 switches in each block
- DS200SIOBH1AAA I/O control board Equipped with an LED
- DS200SIOBH1ABA I/O control board Has 20 jumpers
- PP881 3BSE092978R1 Touch display module Ability to respond quickly to user operations
- IC697CPX928 Central processing unit Single slot chassis
- IS200TREGH1BEC Emergency turbine protection plate Provides negative electrode function
- F8627X Spare parts module
Popular Searches
- lightning conductor
- Copper Lightning Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
- earthing material
- Clad Steel Ground Rod
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-