Module spare parts HONEYWELL 05701-A-0550
- 100 Piece / Pieces per Month
- xiamen
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
Product Details
Brand Name: | HINEYWELL | Place of Origin: | Austria | Model Number: | HONEYWELL 05701-A-0550 |
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
HONEYWELL 05701-A-0550
The measure mode is the mode of operation upon transmitter power up and is the normal operating state of the transmitter. In this mode, the PV, output state, fault condition state, spike state, and secondary display information are displayed. All other modes of operation and fault information are accessible from the measure mode. BOREDOM SWITCH When any operating mode or state is entered and the measure mode is not returned to after the final step, the transmitter automatically returns to the measure mode of operation after 20 minutes of unattended use. PRIMARY DISPLAY The primary display shows the PV. The value of this variable is dependent on the configured analyzer, temperature compensation type, temperature value, sensor output, and damping value. The engineering units for the PV are dependent only on the configured analyzer (Table 5-1). SECONDARY DISPLAY The secondary display has the ability to show a large array of information. Since the display area only has six characters, only one item can be shown at any given time. Typically, this region displays the process temperature in degrees Celsius. However, it can be changed to display the process temperature in degrees Fahrenheit, output current in milliamperes, sensor type, cell constant, conductivity value and solute name for a concentration analyzer, or firmware revision. Refer to Section 10 for more information. Fault Information Smart Key Fault information is only accessible from the measure mode of operation. It is interrogated through the FAULT info smart key. Table 5-1. Engineering Units Analyzer Type Engineering Unit Concentration parts per million (ppm), parts per billion (ppb), percent (%), user-defined Conductivity µS/cm, mS/cm MEASURE MODE SECONDARY DISPLAY 5 - 2 WTPEEUI520002A1 A fault condition causes the FAULT icon to blink and the FAULT info smart key to appear. These indicators continue to be present as long as the fault condition exists. When pressing the FAULT info smart key, the faults appear in a first in, first out (FIFO) order and the first fault condition is shown in the secondary display. A short text string followed by the fault code is shown sequentially. Depressing the FAULT info smart key progressively moves from one fault to the next until all faults have been shown. Once all faults have been cycled through, the FAULT icon no longer blinks but remains on until removal of all fault conditions. If a new fault condition is detected, the FAULT icon begins to blink to indicate the newly detected condition. For more information on fault conditions and codes, refer to Section 12 and its related procedures. Menu Smart Key The MENU smart key provides access to all other modes of operation. By pressing the MENU smart key, the transmitter moves from one mode of operation to the next. Visual feedback is provided in two manners: the mode indication arrow moves to the next mode, such as CALIBRATE, and the secondary display shows the text string representative of that mode, such as CALIBR. Access into the displayed mode of operation is allowed by pressing the SELECT smart key. The exit to MEASURE smart key provides an escape function to the measure mode. As seen in the screen flow diagram shown in Figure 5-1, pressing the MENU smart key when in the measure mode moves the transmitter into the calibrate mode. Once in the calibrate mode, pressing the exit to MEASURE smart key returns the transmitter back to the measure mode. Pressing the SELECT smart key moves the transmitter into the calibrate states of operation. Pressing the MENU smart key moves the transmitter to the output/hold mode. Use Figure 5-1 to identify the smart key assignments and the resulting a
Contact Us
- Ruichang Mingsheng import and export trade Co., Ltd
- DS200TBQCG1AAA Analog terminal board Has two terminal blocks
- 5SHY5045L0020 Asymmetric IGCT drive
- DS200TCCAG1BAA Simulate I/O modules
- 3500/22M288055-01 Real-time monitoring of industrial equipment
- EPI3382 Digital signal processor
- VMIVME-4116 Analog output board DIN output connector
- PU515A Real-time accelerator
- triconex8110 Security system framework Ensure the safety of the production process
- NFT-801RM3-S Tightening machine equipment Supports multiple feedback modes
- 3500/53 133388-01 Monitoring module
- 3HNA024871-001 Spraying robot module Industrial robot
- IS200TRPAH2AHE Turbine control system
- KDB-FT1600 sensor Have energy management
- M2004HW Controller module Power supply can be managed
- RAC2.2-200-460-A00-W1 Spare parts module
- CG6060/32-4TE1 Communication module Realize automatic control of equipment
- IS220PDIIH1B 336A5026ADP1 Thermocouple input module
- PPC380AE01 HIEE300885R0001 Input module
- IS220PAICH2A Analog input/output module Detects external switching input
- DS200TCEAG1ACB Communication module Support data reading
- IC698CRE030 Built-in Ethernet port Automatic induction switch
- CP451-50 Processor module
- IC698CRE040-HN CPU module microprocessor
- Supports 4G Communication Power Grids Automation Industrial IoT Protocol Gateway
Popular Searches
- lightning conductor
- Copper Lightning Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
- earthing material
- Clad Steel Ground Rod
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-