Module spare parts ICS TRIPLEX T9402
- 100 Piece / Pieces per Month
- xiamen
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
Product Details
Brand Name: | TRIPLEX | Place of Origin: | Austria | Model Number: | ICS TRIPLEX T9402 |
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
ICS TRIPLEX T9402
input, temperature input, and transmitter output. These functions, referred to as calibrate states, include PV calibration, temperature calibration, edit calibration, reset calibration, and output calibration. CALIBRATE STATES The calibrate mode consists of five states. Table 6-1 describes the function of each state. When in the calibrate mode, pressing the NEXT smart key causes the display to sequentially move through each calibrate state. This cycle repeats until either selecting a calibrate state using the SELECT smart key or choosing the escape function by pressing the exit to MEASURE smart key. Figure 6-1 is a screen flow diagram for the calibrate mode of operation. CALIBRATION SEQUENCE Refer to Figure 6-2 for the calibration sequence for the transmitter. Each block of the flow represents a single task that must be completed before continuing with the sequence. In some cases, more than one path can be taken during calibration. For paths that are in parallel, either complete all tasks in all paths before continuing or complete all tasks in only those paths that apply before continuing. At least one path must be completed. Table 6-1. Calibrate States Calibrate State Display Description Conductivity/ concentration CON.CAL Calibrate process sensor input via one-point smart calibration that adjusts offset, slope, or both based on sensor calibration history. Edit EDT.CAL Manually adjust process sensor and temperature offset and slope values. Output OUT.CAL Calibrate transmitter output values to measured values using external validation device. Reset RST.CAL Restore calibration values for process sensor and temperature to factory settings. Temperature TMP.CAL Calibrate temperature sensor input via one-point smart calibration that adjusts offset, slope, or both based on sensor calibration history. CALIBRATION CALIBRATION SEQUENCE 6 - 2 WTPEEUI520002A1 Some blocks contain alphanumeric codes. These codes identify the procedure that describes the steps to complete an indicated task. Complete all steps given in a procedure before continuing to the next procedure. The procedures have check boxes in the margin by each procedural step. When performing a procedure, check each box as each step is completed. By treating each task as a separate entity, the procedures provide an easy method for finding the information needed to perform each task in the calibration sequence.
Contact Us
- Ruichang Mingsheng import and export trade Co., Ltd
- 3HNA024871-001 Spraying robot module Industrial robot
- IS200TRPAH2AHE Turbine control system
- KDB-FT1600 sensor Have energy management
- M2004HW Controller module Power supply can be managed
- RAC2.2-200-460-A00-W1 Spare parts module
- CG6060/32-4TE1 Communication module Realize automatic control of equipment
- IS220PDIIH1B 336A5026ADP1 Thermocouple input module
- PPC380AE01 HIEE300885R0001 Input module
- IS220PAICH2A Analog input/output module Detects external switching input
- DS200TCEAG1ACB Communication module Support data reading
- IC698CRE030 Built-in Ethernet port Automatic induction switch
- CP451-50 Processor module
- IC698CRE040-HN CPU module microprocessor
- Supports 4G Communication Power Grids Automation Industrial IoT Protocol Gateway
- DLT645 IEC104 to MQTT Power Grid IoT Gateway for Data Collection and Transparent Transmission
- RJ45 Ethernet Port DLT645 IEC104 to OPC UA Grid Protocol Converter
- Support SNMP V1/V2 DLT645 IEC104 to Modbus Distribution Protocol Gateway
- MU-TAMT02 HONEYWELL BATTERY EXTENSION MODULE
- 204-450-000-002 IQS452 Meggitt Vibro-Meter New in stock
- 204-450-000-001 IQS452 Meggitt Vibro-Meter New in stock
- TK-PPD011 HONEYWELL Battery Extension Module
- KJ3204X1-BA1 Emerson DeltaV Module High-Side Series 2 Card
- SD-98790 HARRIS Digital Input Board
- 204-677-000-003 TFM677 Meggitt Vibro-Meter New in stock
Popular Searches
- lightning conductor
- Copper Lightning Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
- earthing material
- Clad Steel Ground Rod
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-