Home > Products > Electricity Meters > AMI AMR and DIN Rail Split prepaid Energy Meter Box with CIU
AMI AMR and DIN Rail Split prepaid Energy Meter Box with CIU
- 500000 Box / Boxes per Month
- Shenzhen
- T/T L/C D/P D/A Credit Card PayPal
- Acrel ADF400L-3D 3 circuits single phase 10(80)A High accuracy
- Acrel ADF400L-4H Multi Circuit Electrical Instruments 4 channel 3 phase 3*1(6)A High installation flexibility
- Acrel Multi Circuit Electrical Instruments 2 channel 3 phase 3*10(80)A ADF400L-2S din rail
- Acrel din rail Multi Circuit Electrical Instruments 6 channel single phase 10(80)A High installation flexibility ADF400L-6D
- Acrel 6 channel three phase 3*1(6)A High installation flexibility din rail ADF400L-6H Multi Circuit Electrical Instruments
- Acrel ADL3000-E Electrical Measuring Instrument 3 Phase Digital Energy Meter support 2-31st
Product Details
Place of Origin: | Guangdong, China | Brand Name: | CALIN | Model Number: | DDSY168 |
Display Type: | Digital Only | Phase: | Single Phase | Measuring Energy Range: | 5(60)A |
Accuracy Class: | Class1 | Output Voltage: | 230V | Operating Temperature: | -25 ~+70 |
Dimensions: | 150mm*400mm*400mm |
Product Description
1. General Descriptions
Model DIN-BOX-168 box (hereafter referred as Tbox) is a multifunction metering solution composed of meter Box, Measurement & Control Unit (MCU), Data Concentrator (DC) and User Interface Unit (UIU). Each Tbox can access the farend servers via GPRS, so that the administrators can remotely operate Tboxes and read all the meters' energy consumption information. It can help utility companies to largely improve the management efficiency of their power grids, and reduce the management cost. For users, UIUs installed in their homes could achieve energy consumption data from box via RS485 communication, and display to users, so that it is not only convenient for them to read data, but also avoid disruption of energy measurement. Thus, this is a complete metering box solution which combines measurement, use and management of energy.
The box is composed of PC (polycarbonate) cover and ABS base, with performance of reliable insulation, high strength, good flaming resistance, anticorrosion, antiaging and lifetime of over 10 years. It could be widely used in housing construction or civil power grids transformation, with features of multiple combinations of different metering units, easy installation, hidden cable connection and safe operation.
No. | Item | Instructions |
1 | Current | Total threephase maximum current: 256A. Max current of one singlephase meter: 80A. |
2 | Connection Cables | 1) In the three phases, phases A, B & C respectively use yellow, green and red connection cable, the neutral line uses black or blue cable, and the ground line uses yellow and green cable. 2) The cables for internal meters shall be at least BV16mm2 cooper cables. 3) The communication cables should be coppercore twistedpair cables with cross section no less than 0.7mm2. 4) The general cable for each phase shall be copper cable of at least BV50mm2. |
3 | Meter box with PC cover and ABS base. | 1) Tensile strength: ≥35Mpa 2) Bending strength: ≥65Mpa 3) Distortion temperature: ≥100ºC 4) Flame retardant rating: V0 5) Dielectric strength: ≥12 KV/mm 6) Impact strength: Charpy impact strength≥20kJ/m2 7) Sealing performance: With the performance of waterproof, dustproof and prevent the small animal into the meter box. |
4 | Temperature | 1) Maximum temperature: 55ºC (Average temperature ≤35ºC within 24 hours) 2) Average temperature of the hottest month: 35ºC 3) Minimum temperature:10ºC |
5 | Altitude | Altitude: ≤2000m |
6 | Humidity | 1) Daily average relative humidity ≤ 95% 2) Daily average water vapor pressure ≤ 2.2kpa 3) Monthly average relative humidity ≤ 90% 4) Monthly average water vapor pressure ≤ 1.8kPa |
7 | Lifetime | The expected life time of meter box ≥ 20years |
8 | Class of pollution | ≤ Class 2 |
2.3. Operation Principles
A single set of meter box is made of 1 Box, 12 MCUs, 1 DC and 12 UIUs. The box supplies power to the MCUs, DC and UIUs. The MCUs are used for energy measurement, the UIUs for display of energy and electrical parameters, while the DC for reading & transmitting data from MCUs and communicating with the Server. Communication between MCUs and DC is by RS485, between UIUs and DC is by RS485, while between DC and Master Station System is by GPRS.
When the administrators need to read the meter data, below steps should be taken:
1) The administrators send data reading command from the browser interface;
2) The Server will receive the command and send to the DC via GPRS communication;
3) The DC transmits the command to the MCUs and collects the data;
4) The DC sends the data to the browser interface;
5) The data will be saved in the database during this process.
Users can input some codes on the UIUs' keyboards to check and view their energy consumption data. The displayed data are stored in the UIUs, and the DC will keep sending and upgrading the latest energy consumption data to the UIUs.
2.4. Installation Size
3. Components & Parameters
3.1. List of Components
Table 3.1 List of Components
No. |
Model |
Name of Components |
Application |
1 |
Tecun DDSY168 | Singlephase Twowire Meter (MCU) |
Measurement |
2 | Meter Holding Rack | To hold the MCUs firmly. | |
3 | Tecun DC01 | Data Concentrator | Data collection |
4 | Locking device | To lock the meter box | |
5 | RS485 Connection Block | To provide RS485 communication ports to UIUs | |
6 | Cover Opening Detector | To detect the opening of meter box cover | |
7 | Output Terminals | To output power to the users' homes | |
8 |
Vertical Installation Bars | To be installed vertically in the backside of meter box, for fixing the meter box onto the pole or wall. | |
9 | Horizontal Installation Bars | To be installed horizontally in the backside of meter box, for fixing the meter box onto the pole. | |
10 |
Hoop | To be installed in the backside of meter box, used for fixing the meter box onto the pole. | |
11 | Input Terminals | To input power from threephase power grid. | |
12 |
Neutral Line Terminals | Threephase input neutral line terminals and output neutral line terminals. | |
13 |
Cable Fixer | To fix the cables, avoid cables' shaking and prevent water dropping into box from cable entrances. | |
14 |
Tecun DDSY168 |
User Interface Unit (UIU) | To be installed in user's homes for users to check the energy consumption information. |
Contact Us
- Shenzhen Vlinstar Electronic Technology Co., Ltd.
- Contact namewenly liu
- Phone86-0755-23012231
- AddressBuilding 3,Chaohuilou Tech Park,No.119,Huating Road,Longhua New District Shenzhen,Guangdong
All in one pc | Electricity Meters | laptops | LED monitor |
Mini pc | New Products | Smart band | tablet pc |
water meter |
- Acrel ADL3000-E/C 7P three phase multi-function energy meter supporting infrared communication 3 split transformers included
- Acrel three phase smart energy meter LED display 2DI2DO cut out 67*67mm AMC72-E4/KC Accuracy level 0.5
- Acrel Intelligent power collection and monitoring device AMC72L-E4/KC three phase LCD display 2DI2DO panel size 75*75mm
- Acrel with LCD display NB communication Multi-loop intelligent power collection and monitoring device 6 switching inputs
- Acrel 4G communication DC multi-circuit intelligent power collection and monitoring device is applied to tower base stations
- Acrel connect to12 single-phase DC circuits at the same timewith LCD display, Full electrical parameter measurement AMC200L-12DE
- Acrel AC multi-loop intelligent power acquisition and monitoring device With LCD display, 1 channel RS485 AMC200L-4E3
- Acrel for hospital operating room AID150 medical digital centralized alarm insulation display instrument indicator device
- Acrel insulation monitoring device multiple fault indication function Mainly used in IT power distribution systems AIM-T300
- Acrel Din Rail Energy Meter ACR10R-D36TE Solar Din Rail Energy Meter Single Phase LCD RS485 Modbus RTU DIN 35mm AC 85-265V/ DC 100-350
- Acrel ACR10R-D24TE single phase intelligent solar inverter energy meter power monitor with RS485 connection
- Acrel PV/Solar inverter energy meter LCD display RS485 communication single phase ACR10R-D16TE
- Acrel ACR10R-D10TE LCD display for PV/Solar din rail RS485 single phase multifunction power meter
- Acrel inner diameter of transformer16mmADW310-HJ-D16/C single phase wireless energy meter RS485communication
- Acrel ADW310-HJ-D10/WF WF communication single phase IOT smart energy meter din rail type Read data remotely
- Acrel ADW310-HJ-D10/C single phase RS485communication inner diameter of transformer 10mm
- Acrel ACR220ELH three phase Embedded network power meter LCD display Intelligent and digital, it is widely used in various control systems.
- Acrel Multi Circuit Electrical Instruments din rail 9 channel single phase 10(80)A High installation flexibility ADF400L-9D
- Acrel Multi Circuit ADF400L-10H din rail Electrical Instruments 10 channel three phase 3*1(6)A High installation flexibility
- Acrel three phase Electrical Instruments ADF400L-12H din rail Multi Circuit 12 channel 3*1(6)A High installation flexibility
- Acrel three phase ADF400L-6S Multi Circuit Electrical Instruments 6 channel 3*10(80)A High installation flexibility
- Acrel Multi Circuit Electrical Instruments 6 channel three phase 3*10(80)A High installation flexibility din rail ADF400L-6S
- Acrel ADF400L-2H din rail 2 channel Multi Circuit Electrical Instruments three phase 3*1(5)A High installation flexibility
- Acrel 1 channel three phase 3*10(80)A High installation flexibility ADF400L-1S din rail Electrical Instruments Multi Circuit
Popular Searches
Recommended Products
- Acrel ADF400L-3D 3 circuits single phase 10(80)A High accuracy
- Acrel ADF400L-4H Multi Circuit Electrical Instruments 4 channel 3 phase 3*1(6)A High installation flexibility
- Acrel Multi Circuit Electrical Instruments 2 channel 3 phase 3*10(80)A ADF400L-2S din rail
- Acrel din rail Multi Circuit Electrical Instruments 6 channel single phase 10(80)A High installation flexibility ADF400L-6D
- Acrel 6 channel three phase 3*1(6)A High installation flexibility din rail ADF400L-6H Multi Circuit Electrical Instruments
- Acrel current transmitter input AC 0-1/5A output 4-20mA power AC/DC 85-270V BD-AI
- Acrel Active power transmitter AC/DC85-270V 1 Channel analog output BD-3P
- Acrel BD-4E Multi-power digital transmitter 2 channels energy impulse output Rs485 modbus-RTU
- Acrel BD-4EA transmitter 2 channels energy impulse output Rs485 modbus-RTU Multi-power digital
- Acrel transmitter AC/DC85-270V 1 Channel analog output 4-20mA BD-4P Active powe
- Used Temperature And Humidity Test Chamber High And Low Temperature Test Chamber Climate Aging Testing Machine
- JINGYAN Low Temperature Test Chamber Constant Temperature And Humidity Machine Environmental Aging Test Chamber
Find Similar Products By Category
- Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
wenly liu
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-