Home > Products > high-voltage fuse > High-voltage current-limiting fuse is used for Transformer Protection( XRNT-hrc fuse)3.6KV
High-voltage current-limiting fuse is used for Transformer Protection( XRNT-hrc fuse)3.6KV
- 1000 Piece / Pieces per Month
- Shanghai or Ningbo
- T/T L/C D/P D/A Credit Card PayPal
Product Details
Place of Origin: | Zhejiang, China | Brand Name: | SR(shuguang fuse) | Model Number: | XRNT1( type S ) |
Usage: | High Voltage | Breaking Capacity: | High | Safety Standards: | IEC |
Product Description
Applications
H.V current-limiting fuses type S is mainly used in AC50Hz,rated voltage 3.6~40.5KV,rated current up to 200A circuit for protection transformers and power equipments from overload and short-circuit.It can also be used with load switch,vacuum contact.
It conforms to IEC282-1,GB15166.2 and DIN standard.
Design Features
S type H.V HRC current-limiting fuses is insert installation.The striker parallers to the fuse element made from pure silver.They are sealed in the fuse tube filled with chemically treated high-purity quartz sand.The fuse tube is made from heat resistance,high duty ceramic or expoxy glass.
When fault circuit happens,the fuse link melts,the high-resistant metal wire paralleling to fuse links melts immediately at the appearance of the arc,and the striker jumps out to push the chained equipment contact, signaling the melting automatically cuttig the circuit.
The striker has spring type striker jumps out to push ethe chained equipment contact,signaling the melting automatically cutting the circuit.The striker has spring type striker use high pressure caused by the lighting powder to push the striker.
S type H.V.HRC current-limiting fuses has many merits as high current-limiting ablilty,high breaking capacity,quick and punctual in action,reliable in performance.
DIN HRC "S" type high voltage fuse for transformer protection:
1. According to bussmann DIN "S" type high performance back-up fuse
2. Comply with IEC282-1, DIN, BS
3. This fuse is intended to protect distribution networks and transformer, for indoor as well as outdoor use.
4. Any other specifications can be designed specially.
Basic Data
model | Rated voltage (KV) | rated current of the fuse links (A) | Rated breaking current (KA) | dimensions (mm) | ||
Foreign | Department | |||||
SDO.J | XRNT1 | 3.6 see figure 1 | 6.3/10/16/20/25/31.5/40 | 50 | 51 | 192 |
SDL.J | XRNT1 | 7.2 see figure 1 | 6.3/10/16/20/25/31.5/40/50/63 | 50 | 51 | 292 |
SFL.J | XRNT1 | 7.2 see figure 1 | 80/100/125/160 | 50 | 76 | 292 |
SDL.J | XRNT1 | 12 see figure 1 | 6.3/10/16/20/25/31.5/40 | 50 | 51 | 292 |
SFL.J | XRNT1 | 12 see figure 1 | 50/63/71/80/100 | 50 | 76 | 292 |
SKL.J | XRNT1 | 12 see figure 1 | 125 | 50 | 76 | 292 |
SXL.J | XRNT1 | 12 see figure 1 | 160/200 | 50 | 88 | 292 |
SDM.J | XRNT1 | 24 see figure 2 | 6.3/10/16/20/25/31.5/40 | 40 | 51 | 442 |
SFM.J | XRNT1 | 24 see figure 1 | 50/63/71/80/100 | 40 | 76 | 442 |
SKM.J | XRNT1 | 24 see figure 1 | 125 | 40 | 76 | 442 |
SXM.J | XRNT1 | 24 see figure 1 | 160 | 40 | 88 | 442 |
SDQ.J | XRNT1 | 40.5 see figure 3 | 3.15/6.3/10/16/20/25 | 31.5 | 51 | 537 |
SFQ.J | XRNT1 | 40.5 see figure 3 | 31.5/40 | 31.5 | 76 | 537 |
SXQ.J | XRNT1 | 40.5 see figure 3 | 63 | 31.5 | 88 | 537 |
Note:under stipulated comdition,min.breaking current of fuses could be as high as 2.5~3 times than rated current.
Striker: N-without striker; A-powder type; D-spring type.
Transformer capacity (KVA) | Transformer primary voltage | |||
7.2 (KV) | 10(KV) | 20(KV) | 30(KV) | |
Fuse model/ rated current(A) | Fuse model/ rated current(A) | Fuse model/ rated current(A) | Fuse model/ rated current(A) | |
50 | SDL.J-7.2KV/8A | SDL.J-12KV/6.3A | SDM.J-24KV/3.15A | SDQ.J-40.5KV/3.15A |
100 | SDL.J-7.2KV/16A | SDL.J-12KV/10A | SDM.J-24KV/6.3A | SDQ.J-40.5KV/6.3A |
125 | SDL.J-7.2KV/20A | SDL.J-12KV/12A | SDM.J-24KV/6.3A | SDQ.J-40.5KV/6.3A |
160 | SDL.J-7.2KV/25A | SDL.J-12KV/16A | SDM.J-24KV/8A | SDQ.J-40.5KV/6.3A |
200 | SDL.J-7.2KV/31.5A | SDL.J-12KV/20A | SDM.J-24KV/10A | SDQ.J-40.5KV/8A |
250 | SDL.J-7.2KV/40A | SDL.J-12KV/25A | SDM.J-24KV/12A | SDQ.J-40.5KV/10A |
300/315 | SDL.J-7.2KV/50A | SDL.J-12KV/31.5A | SDM.J-24KV/16A | SDQ.J-40.5KV/10A |
400 | SDL.J-7.2KV/63A | SDL.J-12KV/40A | SDM.J-24KV/20A | SDQ.J-40.5KV/16A |
500 | SDL.J-7.2KV/80A | SDL.J-12KV/50A | SDM.J-24KV/25A | SDQ.J-40.5KV/16A |
630 | SDL.J-7.2KV/100A | SDL.J-12KV/63A | SDM.J-24KV/31.5A | SDQ.J-40.5KV/20A |
750/800 | SDL.J-7.2KV/125A | SDL.J-12KV/80A | SDM.J-24KV/40A | SDQ.J-40.5KV/25A |
1000 | SDL.J-7.2KV/160A | SDL.J-12KV/100A | SDM.J-24KV/50A | SDQ.J-40.5KV/31.5A |
1250 | SDL.J-12KV/125A | SDM.J-24KV/63A | SDQ.J-40.5KV/40A | |
1600 | SDL.J-12KV/160A | SDM.J-24KV/80A | SDQ.J-40.5KV/50A | |
2000 | SDL.J-12KV/200A | SDM.J-24KV/100A | SDQ.J-40.5KV/63A |
Welcome to contact us to more details. Some details could be ordered according to the requirement of customers.
Drawing
Contact Us
- Wenzhou Shuguang Fuse Co., Ltd.
- Contact namevilling wong
- Phone86-577-6172872
- AddressNo. 431, Daxing West Road, Liushi Town, Yueqing
auto fuse& autofuse holder | drop-out fuse | fuse link | high-voltage fuse |
insulator | lightning arrester | low voltage fuse | New Products |
- MICROTEMP® 91 °C thermal cutoffs from Therm-O-Disc
- MICROTEMP® 84 °C thermal links from Therm-O-Disc
- MICROTEMP® 167 °C thermal fuses/thermal cutoffs/TCO from Therm-O-Disc
- Conjoined Bar Fuse Disconnector
- fuse switch
- VRK5-500A250VACDC
- VRK5-400A250VACDC
- VRK5-200A250VACDC
- VRK5-125A250VACDC
- VRK5-100A250VACDC
- VRK5-90A250VACDC
- VRK5-80A250VACDC
Popular Searches
Find Similar Products By Category
- Electrical Equipment & Supplies > Fuses
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
villing wong
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-