- Chongqing Enrich Engineering and Technology Co., Ltd
- China Manufacturer with main products:hydropower plant equipments ,electric power equipments ,power distribution equipments ,hydro turbine generator ,Industrial water filter&oil purifier ,Instrument transformer ,Power quality monitoring&improvement ,Reactor/Inductor ,Busduct ,Circuit breaker&Isolating switch&Load switch ,Filter press ,Slurry Pump
Home > Products > Instrument transformer > 10kv 12kv 24kv 33kv to 550kv External or Built in Type Epoxy Resin Bushing Current Transformer for Power Transformer and Circuit Breaker with Stainless Cover Bushing Type Current Transformer Bushing Current Transformer CT for Switchgear Generator GIS
10kv 12kv 24kv 33kv to 550kv External or Built in Type Epoxy Resin Bushing Current Transformer for Power Transformer and Circuit Breaker with Stainless Cover Bushing Type Current Transformer Bushing Current Transformer CT for Switchgear Generator GIS
- 50000 Piece / Pieces per Month
- Chongqing
- T/T
- 15 days
Product Details
Brand Name: | Enrich | Place of Origin: | China | Model Number: | LRZ(G)(B)(T)(1,2,3,4)-20 |
Usage: | Current | Phase: | Single | Coil Number: | Autotransformer |
Coil Structure: | Toroidal |
Product Description
0.5-35kV Epoxy/Epoxide resin current transformer
0.5-35kV Epoxy resin through-wall type current transformer
15-24kV bushing current transformer
LRZ(G)(B)(T)(1,2,3,4)-20(A,A1,A2,A/2,B,B1,B2,C,φ200,φ240)bushing current transformer
Model description
LRZ(G)(B)(T)(1,2,3,4)-20(A,A1,A2,A/2,B,B1,B2,C,φ200,φ240)
L: Current transformer
R:Bushing type
Z: Casting insulation
G: Paint-immerged insulation
B: With protective class
T: Transient protection
(1,2,3,4): Design no.
20: Rated voltage(kV)
(A,A1,A2,A/2,B,B1,B2,C,φ200,φ240): Structure code
LRG1-20A
LRG1-20B1
LRG1-20C
LRGB1-20A
LRGB1-20B1
LRGB1-20C
LRG1-20B2
LRGB1-20B2
LRGBT1-20A
LRGBT1-20B1
LRGBT1-20B2
LRGBT1-20C TPY Z2n=50VA, (COSφ=1.0), C-100ms-O, Tp=265ms, Kssc=2.5
LRZ1-20A
LRZB1-20A
LRZ1-20B
LRZB1-20B
LRZ1-20C
LRZB1-20C
LRZ4-20/φ200
LRZB4-20/φ200
LRZ4-20/φ240
LRZB4-20/φ240
LRGBT2-20A TPY Z1n=50VA, (COSφ=1.0), C-100ms-O, Tp=265ms, Kssc=2.5
LRG2-20A2
LRGB2-20A2
LRG2-20A/2
LRGB2-20A/2
LRZ(B)2-20A1-L(T)
LRZ(B)2-20B1-L(T)
LRZ2-20A2-L(T)
LRZB2-20A2-L(T)
LRZB2-20B2-L(T)
LRG3-20A
LRGB3-20A
LRGBT3-20A TPY Z2n=50VA, (COSφ=1.0), C-100ms-O, Tp=265ms, Kssc=5
LRG3-20B
LRGB3-20B
LRGBT3-20B TPY Z2n=50VA, (COSφ=1.0), C-100ms-O, Tp=265ms, Kssc=2.3
LRG3-20C
LRGB3-20C
LRGBT3-20C TPY Z2n=50VA, (COSφ=1.0), C-100ms-O, Tp=350ms, Kssc=4
Note: The voltage rate is the voltage of generator outlet bushing, the current transformer voltage rate is 0.5kV.
LRB-126(145)/330(320) bushing current transformer
Type description
LRB-126(145)/330(320)
L: Current transformer
R: Bushing type
B: With protective class
126(145): Rated voltage(kV)
330(320): Product height
LRB-126/330
LRB-145/320
300-600/5 0.2S/0.5S/5P20/5P20
600-1200/5 0.5S/5P40/5P40
600-1200/5 0.2S/0.5S/5P20/5P20/5P20
800-1600/5 0.2S/0.5/5P30/5P30
Note: Customized products according to customer’s parameters are available.
Rated primary current I1n(A) | Thermal current/second (kA effective value) Ith/1s (kA r.m.s) | Dynamic stable current (kA peak) Idyn | Accuracy class combination 1S/2S/3S/4S | Rated secondary output(VA) | Surface creepage distance(mm) |
Double transformation ratio | Single transformation ratio | Thermal current/4 seconds (kA effective value) Ith/4s (kA r.m.s) | two transformation ratio | three transformation ratio | Short time thermal current (kA effective value) Ith (kA r.m.s) |
Accuracy limit factor ALF 15, 20,25,30 | Porcelain bushing creepage distance(mm) | Rated current ratio(A) | Rated resistance burden Rb(Ω) 7.5,10,15,20 | Rated symmetrical short-circuit current factor K 10,15,20 | Primary time constant Tp 40,60,80,100 |
Duty cycle C-0.1s-O C-0.1(0.04)s-O C-0.1s-O-0.5s-C-0.1(0.04)s-O | Rated ampere-turn | Primary turn through core | Power factor COSφ=0.8(lag) | Through primary busbar | Rated insulation level(kV) |
Contact Us
- Chongqing Enrich Engineering and Technology Co., Ltd
- Contact nameGuangjian Duan
- Phone86-23-62540401
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrel measuring rated current 250-400A low voltage leakeage CT Residual current transformer AKH-0.66/L L-100
- Acrel Applied to residual current signal collection residual current transformer AKH-0.66/L L-200 rated current 800-1500A
- Acrel AKH-0.66/L L-80 rated current 100-250A Applied to residual current signal collection measurement current transformer
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrelrated current 800-1500A Applied to residual current signal collection residual current transformer AKH-0.66/L L-200
- Acrel AKH-0.66/L L-45 residual current transformer rated current 16-100A Applied to residual current signal collection
- Acrel smart AC current transformer BA20(II)-AI/V Can be widely used in industrial automation fields
- Acrel smart AC electrical transducer BA50(II)-AI/V Mainly detects the leakage current of the electrical system
- Acrel BA50L(II)-AI/V smart AC electrical current sensor Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V smart AC electrical current sensor
- Made in China Three phase dry type transformer SG-100VA for thermal power plant
- Flyback transformer
- Lan transformer
- НЕФТЯНОЕ МЕСТОРОЖДЕНИЕ SHENGDONG SHENGLI газогенератор мощностью 500 кВт T12V190
- shengdong shengli oil field 500KW natural gas generator T12V190ZL
- B6190 G6190 200KW diesel engine used in ship boat spare parts
- B12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BH12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- AL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600lw
- Acrel smart AC electrical current sensor BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/I AC current sensor in AC0-(0.1-1)A out 4-20mA/0-20mA Real-time monitoring of AC current in the power grid
- Acrel smart AC electrical transducer BA50(II)-AI/V Mainly detects the leakage current of the electrical system
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- voltage transformer
Find Similar Products By Category
- Electrical Equipment & Supplies > Transformers
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Guangjian Duan
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-