Home > Products > P+F > Pepperl-fuchs Explosion Protection KFD0-CS-EX1.51P Part no:072147 With Good Price In Stock
Pepperl-fuchs Explosion Protection KFD0-CS-EX1.51P Part no:072147 With Good Price In Stock
- 1000 Piece / Pieces per Month
- Wuhan,China
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Product Details
Brand Name: | Pepperl-fuchs | Place of Origin: | Indonesia | Model Number: | KFD0-CS-EX1.51P |
Product Description
Pepperl-fuchs Explosion Protection KFD0-CS-EX1.51P Part no:072147 With Good Price In Stock
Pepperl+Fuchs is a leading supplier of automation equipment for a wide range of industries and has been associated with safety in hazardous areas for decades. Our deep expertise enables us to offer a complete range of automation solutions for the process automation industry.
The product portfolio includes intrinsic safety isolators, Zener barriers, signal conditioners, fieldbus technology, Remote I/O, HART interfaces, level measurement, purge & pressurization systems, Human Machine Interfaces (HMI) for hazardous environments, custom cabinets, and junction boxes.
We provide process industry companies all over the world with proven components and tailor-made solutions for a diverse range of applications. The branches that we cover include the oil and gas industry, petrochemical, chemical industry, pharmaceutical industry, as well as wastewater treatment plants, and power technology.
1. General Introduction
It transfers the analog input signal to the safe area as an isolated current value. Digital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally. If the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 8, 9 and 11, 12 can be used. Test sockets for the connection of HART communicators are integrated into the terminals of the device
2. General Specification for KFD2-CRG2-EX1.D
Model | KFD0-CS-Ex2.51P |
General specifications | |
Signal type | Analog input |
Functional safety related parameters | |
Safety Integrity Level (SIL) | SIL 2 |
Supply | |
Connection | Power Rail or terminals 23+, 24- |
Rated voltage Ur | 20 ... 35 V DC |
Rated current Ir | approx. 130 mA |
Ripple | within the supply tolerance |
Power dissipation | 2 W |
Power consumption | 2.5 W |
Interface | |
Programming interface | programming socket |
Input | |
Connection side | field side |
Connection | terminals1, 2, 3 |
Input I | |
Input signal | 0/4 ... 20 mA |
Available voltage | ≥ 15 V at 20 mA |
Open circuit voltage/short-circuit current | 24 V / 33 mA |
Line fault detection | breakage I <0.2 mA; short-circuit I > 22 mA |
Input resistance | 45 Ω (terminals 2, 3) |
Output | |
Connection side | control side |
Connectio | output I: terminals 10, 11, 12 output II: terminals 16, 17, 18 output III: terminals 8+, 7- |
Output signal | 0 ... 20 mA or 4 ... 20 mA |
Output I, II | signal, relay |
Contact loading | 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A |
Mechanical life | 5 x 107 switching cycles |
Output III | Signal, analog |
Current range | 0 ... 20 mA or 4 ... 20 mA |
Open loop voltage | ≤ 24 V DC |
Load | ≤ 650 Ω |
Fault signal | downscale I ≤ 3.6 mA, upscale I ≥ 21 mA (acc. NAMUR NE43) |
Energized/De-energized delay | 0 ... 250 s , adjustable |
Transfer characteristics | |
Deviation | at 20 °C (68 °F), 0/4 ... 20 mA ≤± 10 A incl. calibration, linearity, hysteresis, loads and supply voltage |
Input I | |
Accuracy | <30 μA |
Influence of ambient temperature | 0.005 %/K (50 ppm) |
Reaction time | <650 ms at bounce from 0 ... 20 mA at the input, 90 % of output full-scale value |
Rise time/fall time | 20 μs |
Settling time | 200 μs |
Galvanic isolation | |
Input/Other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Vef |
Output I, II/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Mutual output I, II, III | Mutual output I, II, III |
Indicators/settings | |
Display elements | LED display |
Control elements | Control panel |
Configuration | via operating buttons via PACTware |
Labeling | space for labeling at the front |
Directive conformity | |
Electromagnetic compatibility | |
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Low voltage | |
Conformity | |
Electromagnetic compatibility | NE 21:2011 |
Degree of protection | IEC 60529:2001 |
Ambient conditions | |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
3. Assembly
4. Connection
KFD0-CC-EX1
KFD0-TR-EX1
KFD0-TT-EX1
KFD2-PT2-EX1
KFD2-PT2-EX1-1
KFD2-PT2-EX1-4
KFD2-PT2-EX1-5
KFD2-VR-EX1.18
KFD2-VR-EX1.19
KFD0-CS-EX1.50P
KFD0-CS-EX2.50P
KFD0-CS-EX1.51P
KFD0-CS-EX2.51P
KFD0-CS-EX1.53
KFD0-CS-EX2.53
KFD2-GU-EX1 PAR.
KFD2-PT2-EX1-Y98312
KFD2-CD-EX1.32
KFD2-CD-EX1.32-10
KFD2-CD-EX1.32-1
KFD2-CD-EX1.32-12
KFD2-CD-EX1.32-13
KFD2-CD-EX1.32-15
KFD2-CD-EX1.32-2
KFD2-CD-EX1.32-21
KFD2-CD-EX1.32-3
KFD2-CD-EX1.32-5
KFD2-CD-EX1.32-6
KFD2-CD-EX1.32-8
KFD2-CD-EX1.32-9
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8
Contact Us
- HONGKONG XIEYUAN TECH CO., LIMITED
- Contact nameWindy
- Phone86-159-72199006
- Addressjianghan Wuhan,Hubei
Emerson | P+F | Danfoss | Allen-Bradley |
Yokogawa | ABB | MTL | Fluke |
PHOENIX | Schneider Electric | YTC | Honeywell |
Rosemount | Siemens | Krohne | E+H |
Other Brands |
- Siemens plc 6ES7 321-1BH02-0AA0 SIMATIC S7-300 Digital input SM 321 6ES73211BH020AA0
- 6ES73211BH020AA0 simen plc S7-1200 I/O module 6ES7321-1BH02-0AA0
- Original ABB TU838 3BSE008572R1 module
- Original ABB 3BSE038415R1 AO810V2 Analog Output 8 ch I/O Modules
- ABB PROFIBUS module CI840A 3BSE041882R1 PROFIBUS DP-V1
- Servo high temperature vacuum hot press Electric cylinder high pressure and high precision vacuum press 450 degrees Celsius, 5 tons, 10 tons
- HAILUNDA GZC-TF21 15.6 inch screen vacuum laminating machine OCA optical glue vacuum pressing machine
- PIONEER MAGNETICS PM3398B-6-1-3-E 80026-172-24 Digital input I/O module
- EMERSON A6740 RELAY MODULE
- EMERSON A6410 Expansion monitoring module
- EMERSON A6210 Axis vibration monitoring card
- EMERSON A6220 monitor module
- EMERSON A6110 Low pressure differential regulator
- GE 369-HI-R-M-F-E-H-E Motor management relay
- VIBRO-METER VM600 RPS6U 200-582-600-013 SCR module
- VIBRO-METER VM600 RLC16 200-570-000-111 200-570-101-015 Relay card
- VIBRO-METER VM600 MPC4 200-510-071-113 200-510-111-034 MPC4 Mechanical Protection Card
- VIBRO-METER VM600 IOCN 200-566-000-112 200-566-101-013 IOCN Card
- VIBRO-METER VM600 IOCN 200-566-000-112 200-566-101-013 IOCN Card
- VIBRO-METER VM600 IOC16T 200-565-000-013 200-565-101-013 I/O module
- VIBRO-METER VM600 IOC4T 200-560-000-111 200-560-101-017 Vibration monitoring and protection system
- VIBRO-METER VM600 CPUM 200-595-067-114 Central processing unit module
- VIBRO-METER VM600 CMC16 200-530-025-014 200-530-111-013 Condition monitoring
- VIBRO-METER VM600 ABE040 204-040-100-011 system rack
Popular Searches
- lightning conductor
- Copper Lightning Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
- earthing material
- Clad Steel Ground Rod
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Windy
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-